Electrical panels with variable speed drives
speed for water pumps
Autómex’s constant pressure system panels provide reliability in operation and guarantee excellent control and protection of the pumps, saving energy and with less downtime for the user.
Its main features are:
- Saving energy consumption by eliminating the start-up peak
- Specialized software for constant pressure application.
- Sleep booster function – Tank filling to maintain pressure.
- Protection of pipelines in the absence of light with soft start.
- Reduced mechanical wear of the pump by progressive start-up.
- Pump rotation and back-up system according to need
- Dry running protection of pumps
- Pump demand addition function
- Continuous system monitoring
ATX electrical panels for constant pressure systems with variable speed drives with vector technology and a PLC as system master in charge of the management and operation of the pumping system. The control of the drives is done through Modbuss RS435 communication protocol, generating a reliable and stable communication loop. The PLC allows easy integration of special functions and motor control monitoring facilities.
Drinking water 100% constant
Maximum protection for your pumps
Energy consumption savings
Remote monitoring option
Easy programming
Advantages of display board and InomaxTech drives
- Reduced start-up time: The number of parameters entered in the drive is reduced.
- Easy programming: Eas ier configuration due to on-screen parameter entry
- Practical settings: Visualization of the applied settings
- Fault monitoring: Fault and alarm logging
- Fast communication: Increased data transfer speed
- Operating data: Display of variables on screen (pressure, frequency, current, status of storage tanks).
- Tailored to the user: User-friendly and intuitive interface
- Increased security: Possibility of locking the configurations by means of a user password.
- Reduced wiring: Fewer door elements,
decreasing wired logic - Best Aesthetics: Simply, ATX Boards
The PLC is the master
A PLC (Programmable Logic Controller) is an electronic device used in industrial automation to control and monitor the operation of systems and processes. PLCs are used in a wide variety of applications, such as manufacturing, mining, energy, transportation, among others.
PLCs are designed to be programmed and controlled automatically through a specific programming language. These devices typically include components such as digital inputs and outputs, relays, timers, counters and comparators, which allow control and monitoring of system operation.
Boards for constant pressure systems
-
one pump 220 Vac
-
Solar Inverter Board
-
Fire Network Panels
-
Soft Starter
-
Soft Starter
-
Star triangle board
-
Direct start board
- Guarda motor o breaker de protección variadores
- Variadores de velocidad
- Controlador de Sistema de Presión Constante HydroSmart
- Mininterruptor de protección control
- Elementos de mando y señalización en puerta
- Sistema de ventilación automática
- Bornes de conexión, control y potencia
- Bloque o barraje de distribución general
- Accesorios de interconexión
- Marquillado de acuerdo a plano
- Dossier de fabricación por código QR
Tableros ATX una bomba 220 Vac
Referencia | Hp | KW | Tamaño del cofre (mm) | Inomax (Amp) | Mitusbishi (Amp) | Ficha Técnica |
---|---|---|---|---|---|---|
ATX1B22VFP | 2 | 1.5 | 600x400x250 | 9 | 7 | Descargar |
ATX1B32VFP | 3 | 2.2 | 600x400x250 | 10.6 | 10 | Descargar |
ATX1B52VFP | 5 | 3.7 | 700x500x250 | 17 | 16.5 | Descargar |
ATX1B7.52VFP | 7.5 | 5.5 | 800x500x250 | 25 | 23.8 | Descargar |
ATX1B102VFP | 10 | 7.5 | 800x500x250 | 32 | 31.8 | Descargar |
ATX1B152VFP | 15 | 11 | 900x600x300 | 45 | 45 | Descargar |
ATX1B202VFP | 20 | 15 | 1000x700x300 | 60 | 58 | Descargar |
ATX1B252VFP | 25 | 17.5 | 1000x700x300 | 75 | 63 | Descargar |
ATX1B302VFP | 30 | 22 | 1100x800x300 | 90 | 77 | Descargar |
ATX1B402VFP | 40 | 30 | 1300x900x300 | 110 | 125 | Descargar |
Tableros ATX una bomba 440 Vac
Referencia | Hp | KW | Tamaño del cofre (mm) | Inomax (Amp) | Mitusbishi (Amp) | Ficha Técnica |
---|---|---|---|---|---|---|
ATX1B24VFP | 2 | 1.5 | 600x400x250 | 3.7 | 3.6 | Descargar |
ATX1B34VFP | 3 | 2.2 | 600x400x250 | 5.1 | 5 | Descargar |
ATX1B54VFP | 5 | 3.7 | 700x500x250 | 9 | 8 | Descargar |
ATX1B7.54VFP | 7.5 | 5.5 | 800x500x250 | 13 | 12 | Descargar |
ATX1B104VFP | 10 | 7.5 | 800x500x250 | 17 | 16 | Descargar |
ATX1B154VFP | 15 | 11 | 900x600x300 | 25 | 23 | Descargar |
ATX1B204VFP | 20 | 15 | 1000x700x300 | 32 | 29.5 | Descargar |
ATX1B254VFP | 25 | 17.5 | 1000x700x300 | 38 | 31 | Descargar |
ATX1B304VFP | 30 | 22 | 1100x800x300 | 45 | 38 | Descargar |
ATX1B404VFP | 40 | 30 | 1300x900x300 | 60 | 62 | Descargar |
- Guarda motor o breaker de protección variadores
- Variadores de velocidad
- Controlador de Sistema de Presión Constante HydroSmart
- Mininterruptor de protección control
- Elementos de mando y señalización en puerta
- Sistema de ventilación automática
- Bornes de conexión, control y potencia
- Bloque o barraje de distribución general
- Accesorios de interconexión
- Marquillado de acuerdo a plano
- Dossier de fabricación por código QR
Tableros ATX dos bombas 220 Vac
Referencia | Hp | KW | Tamaño del cofre (mm) | Inomax (Amp) | Mitusbishi (Amp) | Ficha técnica |
---|---|---|---|---|---|---|
ATX2B22VFP | 2 | 1.5 | 700x500x250 | 9 | 7 | Descargar |
ATX2B32VFP | 3 | 2.2 | 700x500x250 | 10.6 | 10 | Descargar |
ATX2B52VFP | 5 | 3.7 | 700x600x250 | 17 | 16.5 | Descargar |
ATX2B7.52VFP | 7.5 | 5.5 | 800x600x300 | 25 | 23.8 | Descargar |
ATX2B102VFP | 10 | 7.5 | 800x600x300 | 32 | 31.8 | Descargar |
ATX2B152VFP | 15 | 11 | 900x600x300 | 45 | 45 | Descargar |
ATX2B202VFP | 20 | 15 | 1000X800X300 | 60 | 58 | Descargar |
ATX2B252VFP | 25 | 17.5 | 1100X800X350 | 75 | 63 | Descargar |
ATX2B302VFP | 30 | 22 | 1200x800x300 | 90 | 77 | Descargar |
ATX2B402VFP | 40 | 30 | 1300x800x350 | 110 | 125 | Descargar |
Tableros ATX dos bombas 440Vac
Referencia | Hp | KW | Tamaño del cofre (mm) | Inomax (Amp) | Mitusbishi (Amp) | Ficha técnica |
---|---|---|---|---|---|---|
ATX2B24VFP | 2 | 1.5 | 700x500x250 | 3.7 | 3.6 | Descargar |
ATX2B34VFP | 3 | 2.2 | 700x500x250 | 5.1 | 5 | Descargar |
ATX2B54VFP | 5 | 3.7 | 700x600x250 | 9 | 8 | Descargar |
ATX2B7.54VFP | 7.5 | 5.5 | 800x600x300 | 13 | 12 | Descargar |
ATX2B104VFP | 10 | 7.5 | 800x600x300 | 17 | 16 | Descargar |
ATX2B154VFP | 15 | 11 | 900x600x300 | 25 | 23 | Descargar |
ATX2B204VFP | 20 | 15 | 900x600x300 | 32 | 29.5 | Descargar |
ATX2B254VFP | 25 | 17.5 | 900x600x300 | 38 | 31 | Descargar |
ATX2B304VFP | 30 | 22 | 1200x800x300 | 45 | 38 | Descargar |
ATX2B404VFP | 40 | 30 | 1300x800x350 | 60 | 62 | Descargar |
- Guarda motor o breaker de protección variadores
- Variadores de velocidad
- Controlador de Sistema de Presión Constante HydroSmart
- Mininterruptor de protección control
- Elementos de mando y señalización en puerta
- Sistema de ventilación automática
- Bornes de conexión, control y potencia
- Bloque o barraje de distribución general
- Accesorios de interconexión
- Marquillado de acuerdo a plano
- Dossier de fabricación por código QR
Tableros ATX tres bombas 220 Vac
Referencia | Hp | KW | Tamaño del cofre (mm) | Inomax (Amp) | Mitusbishi (Amp) | Ficha técnica |
---|---|---|---|---|---|---|
ATX3B22VFP | 2 | 1.5 | 800x600x300 | 9 | 7 | Descargar |
ATX3B32VFP | 3 | 2.2 | 800x600x300 | 10.6 | 10 | Descargar |
ATX3B52VFP | 5 | 3.7 | 900x700x300 | 17 | 16.5 | Descargar |
ATX3B7.52VFP | 7.5 | 5.5 | 1000x800x300 | 25 | 23.8 | Descargar |
ATX3B102VFP | 10 | 7.5 | 1000x800x300 | 32 | 31.8 | Descargar |
ATX3B152VFP | 15 | 11 | 1200x800x300 | 45 | 45 | Descargar |
ATX3B202VFP | 20 | 15 | 1200x800x300 | 60 | 58 | Descargar |
ATX3B252VFP | 25 | 17.5 | 1200x800x300 | 75 | 63 | Descargar |
ATX3B302VFP | 30 | 22 | 1300x800x350 | 90 | 77 | Descargar |
ATX3B402VFP | 40 | 30 | 1300x1200x350 | 110 | 125 | Descargar |
Tableros ATX tres bombas 220 Vac
Referencia | Hp | KW | Tamaño del cofre (mm) | Inomax (Amp) | Mitusbishi (Amp) | Ficha técnica |
---|---|---|---|---|---|---|
ATX3B24VFP | 2 | 1.5 | 800x600x300 | 3.7 | 3.6 | Descargar |
ATX3B34VFP | 3 | 2.2 | 800x600x300 | 5.1 | 5 | Descargar |
ATX3B54VFP | 5 | 3.7 | 900x700x300 | 9 | 8 | Descargar |
ATX3B7.54VFP | 7.5 | 5.5 | 1000x800x300 | 13 | 12 | Descargar |
ATX3B104VFP | 10 | 7.5 | 1000x800x300 | 17 | 16 | Descargar |
ATX3B154VFP | 15 | 11 | 1200x800x300 | 25 | 23 | Descargar |
ATX3B204VFP | 20 | 15 | 1200x800x300 | 32 | 29.5 | Descargar |
ATX3B254VFP | 25 | 17.5 | 1200x800x300 | 38 | 31 | Descargar |
ATX3B304VFP | 30 | 22 | 1300x800x350 | 45 | 38 | Descargar |
ATX3B404VFP | 40 | 30 | 1300x1200x350 | 60 | 62 | Descargar |
Remote monitoring
Remote monitoring in electrical panels is a technique used to control and supervise the operation of electrical panels remotely, i.e. from a location other than the location of the panel. This technique is based on the use of monitoring and communication devices that allow the collection and transmission of information on the operation of the board to a centralized platform.
Remote monitoring in electrical panels allows companies to have a real-time view of the operation of their electrical panels, allowing them to detect problems and failures in a timely manner and take measures to correct them before power outages or interruptions occur.
To carry out remote monitoring in electrical panels, it is necessary to install monitoring devices in the panel that collect and transmit the information to a centralized platform. These devices typically include sensors, gauges and other components that allow the collection and transmission of data on the operation of the board.
Applications for Hydrosmart L9 PLUS controllers
Pressure Equipment
- Use with pressure switches.
- Use with 4-20 mA pressure transducer.
On-demand alternation, backup and addition function.
- Dry pump protection by float, electrodes or without them
Ejector Equipment
- Use with floats or electrodes.
- Use with 4-20 mA level transducer
- Use for submersible pumps with internal float.
On-demand alternation, backup and addition function.
-Electronic alarm buzzer and external alarm connection facility.
Lifting Equipment
- Use with floats or electrodes.
-Use with 4-20 mA level transducer.
- Toggle only function.
-Alternation and addition function on demand.
-Dry pump protection by float, electrode or without them.
Main Features
- Manual / Automatic Selector Switch
- Memory recovery when deenergized
- Resetting of work in case of failure or vacuum events
- Display of pump operating time
- Display of the last five faults of each pump
- Overload Protection
- Motor protection Stuck
- High / Low Voltage Protection
- Dry working protection
- Phase loss protection
- Phase reversal protection
- Phase unbalance protection
- Pump cycling protection
- Pump shaft anti-oxidation protection
- 1NA external siren connection facility
- Modbuss RTU communication port
- Easy programming of protection ranges
- Receives signals from NO thermistors - one per pump
- Automatic calibration button
- Pump enable or disable function
- Lock function of operating buttons
Instructions
Download the details of each model by clicking on the first box.